Products/ASTM A193/A193M-26

MATERIAL DATA · COLD FORMING

B5 Bolting Material

Standard-reference composition and finished-component requirements for B5 Bolting Material. Product form, Class, heat treatment and acceptance conditions require separate confirmation; this reference does not establish actual supply or measured heat results.

Supply and technical review · Creation Group accepts supply and technical review enquiries for this product. Dimensions, delivery condition, quantity and inspection documents are confirmed in the order technical agreement after review.

01Applicable standardASTM A193/A193M-26
02Material gradeB5
03Product formhigh-temperature and high-pressure bolting material
04Delivery informationTo be confirmed against the order technical requirements

Material technical data

Only data directly related to this material is shown here. Inspection, equipment, process and packaging information is linked separately.

Enquire this grade

ASTM A193/A193M-26 composition requirements and conditions

Standard reference requirements compiled from ASTM A193/A193M-26. Raw-material composition and the Class, heat treatment and performance conditions of finished components require separate confirmation; these are not actual supply or measured heat results.

Composition: Table 1, physical page 3; mass fraction wt%. Values are upper limits unless ranges, minimum values or conditional requirements are stated separately.

ElementRequirement
C≥ 0.10
Mn≤ 1.00
P≤ 0.040
S≤ 0.030
Si≤ 1.00
Cr4.0—6.0
NiNot specified (must not be assumed 0)
Mo0.40—0.65
CuNot specified (must not be assumed 0)
NbNot specified (must not be assumed 0)
TiNot specified (must not be assumed 0)
VNot specified (must not be assumed 0)
AlNot specified (must not be assumed 0)
NNot specified (must not be assumed 0)

Product-analysis tolerances are separate from the base composition ranges; intentional additions of Bi, Se, Te and Pb are prohibited.

Product-analysis tolerances (wt%, Table 1; must not be added directly to the base composition ranges)
ElementDeviation
C0.01
Mn0.03
P0.005
S0.005
Si0.05
Cr0.10
NiNot listed in the original table (do not enter 0)
Mo0.05
CuNot listed in the original table (do not enter 0)
NbNot listed in the original table (do not enter 0)
TiNot listed in the original table (do not enter 0)
VNot listed in the original table (do not enter 0)
AlNot listed in the original table (do not enter 0)
NNot listed in the original table (do not enter 0)

Product-analysis tolerances are separate from the tabulated requirements. For the same element in the same heat, deviations must not occur both above and below the range. Unless otherwise stated, maximum values allow upward deviations only, ranges allow upward or downward deviations, and minimum values allow downward deviations only. Tolerances must not be added to the tabulated ranges in advance.

Customary-unit properties (Table 2)

Under 1.6, customary units apply unless the order or contract specifies the metric M edition. Under 1.7, the two unit systems are used independently and must not be mixed or combined through conversion. Properties are room-temperature requirements after the corresponding heat treatment; the specific Class, product form, specimen and order require separate confirmation.

GradeClassDiameter conditionHeat treatment / minimum tempering temperatureRm≥ ksiRp0.2≥ ksiA4D≥ %Z≥ %Maximum hardnessFootnotePhysical page
B5Ferritic gradesUp to and including 4 inMinimum tempering temperature 1100 °F100801650Not specified6

    Metric properties (Table 3)

    Under 1.6, customary units apply unless the order or contract specifies the metric M edition. Under 1.7, the two unit systems are used independently and must not be mixed or combined through conversion. Properties are room-temperature requirements after the corresponding heat treatment; the specific Class, product form, specimen and order require separate confirmation.

    GradeClassDiameter conditionHeat treatment / minimum tempering temperatureRm≥ MPaRp0.2≥ MPaA4D≥ %Z≥ %Maximum hardnessFootnotePhysical page
    B5Ferritic gradesUp to M100Minimum tempering temperature 593 °C6905501650Not specified7

      Product form, heat treatment and inspection limitations

      • 9.1.1: Table 2/3 tensile requirements apply at room temperature after heat treatment. Strain-hardened stainless steel components (Class 2/2B/2C) are tested full-size after strain hardening. Where equipment capacity is insufficient, components over 1.500 in. in diameter may be tested using machined specimens. If full-size and specimen results conflict, the full-size results govern. The original dimensional condition is stated only in customary units; no metric endpoint is invented.
      • 9.1.2, 12.1.3: Applicable headed components also require full-size wedge-load testing. The minimum wedge tensile load is calculated from the specified tensile strength and thread stress area. Units: ksi×in² gives kip (×1000 gives lbf); MPa×mm² gives N (÷1000 gives kN). Unnormalized products must not be labelled directly as lbf or kN. Verify the stress area under A962/A962M. Material-specimen properties do not replace applicable finished-component testing; confirm the applicable head type, size and length under 12.1.3.
      • 9.2.1: Hardness requirements follow Table 2/3, with testing under A962/A962M or F606/F606M. A tabulated maximum hardness does not establish that finished-product hardness testing has been completed.
      • 6.1.2, 6.1.3: Water quenching is prohibited when ferritic grades are heat treated after heading or thread forming. Except for the specified B6X exception, material cold drawn for dimensional control after heat treatment must be stress relieved after cold drawing, at a temperature no lower than the original tempering temperature minus 55°C, and mechanically tested after stress relief.

      Contact: website@chqwire.net. This information is for technical material-selection reference only; it is not a quotation, contractual guarantee or heat-specific quality certificate. The applicable standard, order and material certificate govern.

      Application and ordering note

      Chemical composition, mechanical properties, delivery condition and other technical requirements are subject to the currently applicable standard edition, customer drawings and the order technical agreement. Website information does not replace formal quality certification documents.

      What to include in the enquiry

      Carbon equivalent calculator — B5 Bolting Material

      Basis: ASTM A193/A193M-26

      Composition used for calculation and applicability: Carbon-equivalent calculation has not yet been fully verified

      Carbon-equivalent calculation has not yet been fully verified

      A stated upper limit means 0 to that limit. A lower limit alone does not define an upper bound. Missing elements are unknown, not zero. Standard-limit combinations are not measured heat results.

      Carbon equivalent supports weldability assessment; it does not approve cold heading, fastener strength or a welding procedure. These formulas do not directly apply to stainless steels, cast irons or non-ferrous metals.

      Method reference: TWI

      Carbon equivalent calculator →

      Send a technical enquiry

      Contact technical team →

      Material reference data

      Same-grade reference does not establish standard equivalence, supply or substitution approval.

      WhatsApp Technical enquiry →
      Image and content use · Creation Group