← BackMaterial grade directory

TU00

1 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.

Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.

Open condition selection, comparison and carbon-equivalent tools for TU00 →

Material demand assessment

Looking for TU00 material?

Not listed in our catalog? You are welcome to submit your requirements. We assess whether our equipment, production lines and process capabilities suit your grade, product form, dimensions, processing and delivery requirements, then discuss possible processing, trials or supply arrangements.

Feasibility and supply terms are confirmed after technical review. The standard information on this page is not a supply or performance commitment.

Explore products and processing capabilities

TU00 · GB/T 5231-2012

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Copper and copper alloys
Material form
Reference record
Original record status
Original standard verified
Standard edition
GB/T 5231-2012
Table / clause
Table 1, row 1, designation C10100
PDF page references
5

Carbon-equivalent reference

IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category

Composition

ElementComposition requirement
P≤ 0.0003 (lower limit not stated)
Ag≤ 0.0025 (lower limit not stated)
Bi≤ 0.0001 (lower limit not stated)
Sb≤ 0.0004 (lower limit not stated)
As≤ 0.0005 (lower limit not stated)
Fe≤ 0.001 (lower limit not stated)
Ni≤ 0.001 (lower limit not stated)
Pb≤ 0.0005 (lower limit not stated)
Sn≤ 0.0002 (lower limit not stated)
S≤ 0.0015 (lower limit not stated)
Zn≤ 0.0001 (lower limit not stated)
O≤ 0.0005 (lower limit not stated)
Te≤ 0.0002 (lower limit not stated)
Se≤ 0.0003 (lower limit not stated)
Mn≤ 5e-05 (lower limit not stated)
Cd≤ 0.0001 (lower limit not stated)
Cu≥ 99.99 (upper limit not stated)

Applicability and limitations

Mass fraction wt%; GB/T5231—2012, Table 1, row 1, designation C10100. A dash means unspecified and must not be entered as zero; The combined Cu+Ag minimum must not be split into independent minima for Cu and Ag. Table 1, note a: As, Bi and Sb need not be analyzed, but the supplier must guarantee that the respective limits are not exceeded. This standard covers wrought copper and copper-alloy designations and chemical composition; actual supply of cold-heading wire is not inferred. Table 1 Note b: This value is the copper content, obtained by the difference method when Cu≥99.99%; Te/Se/Mn/Cd upper limit is listed separately according to C10100.

Combined limits

Combined-element limits
    Elements requiring measured values from the same heat

      Verification notes

      Each cell in row 1 of Table 1 in the scanned original, together with applicable footnotes, was checked manually
      WhatsApp Technical enquiry →