TP2
2 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.
Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.
Open condition selection, comparison and carbon-equivalent tools for TP2 →Material demand assessment
Looking for TP2 material?
Not listed in our catalog? You are welcome to submit your requirements. We assess whether our equipment, production lines and process capabilities suit your grade, product form, dimensions, processing and delivery requirements, then discuss possible processing, trials or supply arrangements.
Feasibility and supply terms are confirmed after technical review. The standard information on this page is not a supply or performance commitment.
Keep your entries and try again later, or contact website@chqwire.net. If you have already received confirmation, do not submit again.
TP2 · GB/T 5231-2001
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material category
- Copper and copper alloys
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- GB/T 5231-2001
- Table / clause
- Table 1 and footnotes
- PDF page references
- 1、3、4、5、6、7、8、9、10、11、12、13、14
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| P | 0.015 ~ 0.04 |
Applicability and limitations
Mass fraction wt%; Under 2.2, elements with specified lower and upper limits are alloying constituents; a single value is a minimum for copper and a maximum for other elements. A dash means unspecified; it is not entered as zero; Cu+Ag and Ni+Co are subject to combined ranges and are not converted into independent element ranges. The balance remains a balance; subtracting independent maxima does not establish a guaranteed range. Total impurities include all relevant impurities; The sum of listed elements is only a necessary condition and cannot replace complete impurity analysis. Product forms in the original document define the applicable wrought-product scope; they do not establish confirmed supply of cold-heading wire or final properties. Table 1, note 2: As/Sb/Bi need not be analyzed, but the supplier must guarantee that the limit is not exceeded.
Combined limits
- Combined-element limits
- Element coefficient
- Cu
- 1
- Ag
- 1
- Lower limit
- 99.9
- Requirement
- Minimum total Cu + Ag
- Elements requiring measured values from the same heat
- Ag
- Cu
Verification notes
The official GB/T 5231—2001 tables 1–4 and applicable footnotes were checked row by row against the source. The condition conflict for seven grades whose Fe content is incompatible with non-magnetic requirements is retained; it is not applied automatically.TP2 · GB/T 5231-2012
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material category
- Copper and copper alloys
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- GB/T 5231-2012
- Table / clause
- Table 1, row 20, designation C12200
- PDF page references
- 5
- Unit
- Mass fraction (wt%)
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| P | 0.015 ~ 0.04 |
Applicability and limitations
Mass fraction wt%; GB/T 5231-2012, Table 1, row 20, designation C12200; scanned original PDF, PDF physical page 5 (printed page 2). Dashes mean unspecified, not zero. A combined minimum must not be split into independent elemental minima. Clause 2.2: single impurity values in the table are maxima. Unlisted element limits cannot be filled with zero using another edition. Note a to Table 1: analysis of As, Bi and Sb may be omitted, but the supplier must ensure that they do not exceed the table maxima. This standard specifies only wrought copper/copper-alloy designations and chemical composition; it does not establish actual cold-heading wire supply.
Combined limits
- Combined-element limits
- Element coefficient
- Cu
- 1
- Ag
- 1
- Lower limit
- 99.9
- Requirement
- Minimum total Cu + Ag
- Elements requiring measured values from the same heat
- Ag
- Cu