← BackMaterial grade directory

TNI2.4-0.6-0.5

1 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.

Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.

Open condition selection, comparison and carbon-equivalent tools for TNI2.4-0.6-0.5 →

Material demand assessment

Looking for TNI2.4-0.6-0.5 material?

Not listed in our catalog? You are welcome to submit your requirements. We assess whether our equipment, production lines and process capabilities suit your grade, product form, dimensions, processing and delivery requirements, then discuss possible processing, trials or supply arrangements.

Feasibility and supply terms are confirmed after technical review. The standard information on this page is not a supply or performance commitment.

Explore products and processing capabilities

TNi2.4-0.6-0.5 · GB/T 5231-2012

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Copper and copper alloys
Material form
Reference record
Original record status
Original standard verified
Standard edition
GB/T 5231-2012
Table / clause
Table 2, row 10, designation C18000
PDF page references
6
Unit
Mass fraction (wt%)

Carbon-equivalent reference

IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category

Composition

ElementComposition requirement
Cr0.1 ~ 0.8
Si0.4 ~ 0.8
Fe≤ 0.15 (lower limit not stated)

Applicability and limitations

Mass fraction wt%; GB/T 5231-2012, Table 2, row 10, designation C18000; original scan PDF page 6 (printed page 4). Where Cu is marked as the balance, no numerical range is invented; A dash means unspecified and must not be entered as zero. Clause 2.2: single tabulated impurity values are maxima; Manufacturer supply and the chemical composition in this standard require separate confirmation. Table 2, note a: high-copper alloys have copper content between 96.0% and 99.3%; This standard does not establish a guarantee of cold-heading wire supply. Tabulated total impurities ≤0.65%; this is not the maximum for each unlisted element. Table 2, note c: tabulated 1.8%–3.0% is a combined Ni+Co range and must not be split into an independent Ni range.

Combined limits

Combined-element limits
  • Element coefficient
    Ni
    1
    Co
    1
    Lower limit
    1.8
    Upper limit
    3.0
    Requirement
    Table 2, note c: Ni+Co range
Elements requiring measured values from the same heat
  • Co
  • Ni

Verification notes

Scanned original standard Table 2 checked manually cell by cell; continuation-table headings and footnotes b/c/d checked separately.
WhatsApp Technical enquiry →