SUS 430LX
2 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.
Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.
Open condition selection, comparison and carbon-equivalent tools for SUS 430LX →SUS 430LX · JIS G 4305-2021
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material category
- Stainless steel
- Subcategory
- Ferritic stainless steel
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- JIS G 4305-2021
- Table / clause
- Table 5 · Notes a
- PDF page references
- 9、7、10
Carbon-equivalent reference
Estimates are presented separately for each applicable composition condition. Match the actual ordering conditions; ranges must not be combined.
Ti 0.10–1.00% (Ti or Nb)
Nb 0.10–1.00% (Ti or Nb)
Composition record (conditional branches apply; this is not an unconditional requirement)
| Element | Composition requirement |
|---|---|
| C | ≤ 0.03 (lower limit not stated) |
| Si | ≤ 0.75 (lower limit not stated) |
| Mn | ≤ 1 (lower limit not stated) |
| P | ≤ 0.04 (lower limit not stated) |
| S | ≤ 0.03 (lower limit not stated) |
| Cr | 16 ~ 19 |
| Ni | ≤ 0.6 (lower limit not stated) |
Applicability and limitations
The original table specifies Ti or Nb 0.10–1.00%; select the stabilization element actually used; It is not mandatory for both to be satisfied simultaneously. ; Table 5 Note a: Ni≤0.60%. ; Heat-analysis mass fractions wt%; Clause 5.2: Product analysis deviations shall follow JIS G0321 Table 5; items not specified require agreement, and the default heat analysis range shall not be expanded. ; This standard covers cold-rolled stainless steel plate, sheet and strip.; This does not establish applicability to the supply of cold-heading wire.. ; Elements not specified in the table shall not be filled as zero; The conventional low-alloy steel formula for carbon equivalent is not applicable to this type of stainless steel.
Original condition-branch records
Ti 0.10–1.00% (Ti or Nb)
| Element | Composition requirement |
|---|---|
| C | ≤ 0.03 (lower limit not stated) |
| Si | ≤ 0.75 (lower limit not stated) |
| Mn | ≤ 1 (lower limit not stated) |
| P | ≤ 0.04 (lower limit not stated) |
| S | ≤ 0.03 (lower limit not stated) |
| Cr | 16 ~ 19 |
| Ni | ≤ 0.6 (lower limit not stated) |
| Ti | 0.1 ~ 1 |
Nb 0.10–1.00% (Ti or Nb)
| Element | Composition requirement |
|---|---|
| C | ≤ 0.03 (lower limit not stated) |
| Si | ≤ 0.75 (lower limit not stated) |
| Mn | ≤ 1 (lower limit not stated) |
| P | ≤ 0.04 (lower limit not stated) |
| S | ≤ 0.03 (lower limit not stated) |
| Cr | 16 ~ 19 |
| Ni | ≤ 0.6 (lower limit not stated) |
| Nb | 0.1 ~ 1 |
A condition branch must be selected
YesVerification notes
Original Japanese Table 3/5, 5.1/5.2 and note a were visually checkedSUS 430LX · JIS G 4304-2005
Original-source verification is incomplete; this is not a formal standard reference
- Material category
- Stainless steel
- Subcategory
- Ferritic stainless steel
- Material form
- Reference record
- Verification status
- Reference data; original source not verified
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| C | ≤ 0.03 (lower limit not stated) |
| Cr | 16 ~ 19 |
| Mn | ≤ 1 (lower limit not stated) |
| Ni | ≤ 0.6 (lower limit not stated) |
| P | ≤ 0.04 (lower limit not stated) |
| S | ≤ 0.03 (lower limit not stated) |
| Si | ≤ 0.75 (lower limit not stated) |
Applicability and limitations
A match in the materials database does not establish suitability for cold heading or guarantee finished-product strength. Confirmation must consider wire condition, deformation, heat treatment and tests on actual parts.