QSWRCH10A-B · Q/XG 243-2019

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Cold-heading steel
Material form
Wire rod
Original record status
Original standard verified
Standard edition
Q/XG 243-2019
Table / clause
Table 1, row 1
PDF page references
2
Unit
Mass fraction (wt%)

Carbon-equivalent reference

IIW / CEV:0.1300–0.3167Known-element contribution; incomplete value; missing V CEV = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15; an engineering estimate of welding cold-cracking susceptibility for carbon and low-alloy steels.
Pcm(Ito–Bessyo):0.0950–0.1933Known-element contribution; incomplete value; missing V, B Pcm = C + Si/30 + (Mn + Cu + Cr)/20 + Ni/60 + Mo/15 + V/10 + 5B; mainly used for low-carbon low-alloy steels, particularly modern low-carbon pipeline steels; more relevant when C is approximately no higher than 0.11%.
CET:0.1100–0.2250 Independent-element envelope of standard ranges; not measured heat-analysis values CET = C + (Mn + Mo)/10 + (Cr + Cu)/20 + Ni/40; used in welding preheat assessment for ferritic steels, subject to the applicability conditions of EN 1011-2.

Composition

ElementComposition requirement
C0.08 ~ 0.13
Si≤ 0.1 (lower limit not stated)
Mn0.3 ~ 0.6
P≤ 0.03 (lower limit not stated)
S≤ 0.025 (lower limit not stated)
Al≥ 0.02 (upper limit not stated)
Cr≤ 0.2 (lower limit not stated)
Ni≤ 0.2 (lower limit not stated)
Cu≤ 0.2 (lower limit not stated)
Mo≤ 0.1 (lower limit not stated)

Applicability and limitations

Mass fraction wt%; Q/XG 243-2019 heat analysis; Local PDF, page 2. Check product-analysis tolerances under GB/T 222; Heat-analysis ranges are not directly treated as guaranteed product-analysis ranges. The enterprise standard covers passenger-vehicle cold-heading steel wire rod requiring vehicle-manufacturer approval; it does not establish Creation Group stock availability, customer approval or substitution approval. Table 1, merged “other” cell: each of Cr/Ni/Cu is ≤0.20%, Mo≤0.10%.

Combined limits

Combined-element limits
    Elements requiring measured values from the same heat

      Verification notes

      Original Q/XG 243-2019, Table 1 PDF, page 2: rows and merged cells were visually checked