← BackMaterial grade directory

HSI75-3

1 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.

Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.

Open condition selection, comparison and carbon-equivalent tools for HSI75-3 →

HSi75-3 · GB/T 5231-2012

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Copper and copper alloys
Material form
Reference record
Original record status
Original standard verified
Standard edition
GB/T 5231-2012
Table / clause
Table 3, row 65, designation T68320
PDF page references
9
Unit
Mass fraction (wt%)

Carbon-equivalent reference

IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category

Composition

ElementComposition requirement
Cu73.0 ~ 77.0
Fe≤ 0.1 (lower limit not stated)
Pb≤ 0.1 (lower limit not stated)
Mn≤ 0.1 (lower limit not stated)
P0.04 ~ 0.15
Ni≤ 0.1 (lower limit not stated)
Si2.7 ~ 3.4
Cd≤ 0.01 (lower limit not stated)
Sn≤ 0.2 (lower limit not stated)

Applicability and limitations

Mass fraction wt%; GB/T 5231-2012, Table 3, row 65, designation T68320; Scanned PDF, page 9. Zn is the balance; A dash means unspecified; it is not entered as zero. Clause 2.2: single tabulated impurity values are maxima. Tabulated total impurities ≤0.6%; verify using measured contents of the impurity elements specified in the standard. This standard provides composition designations for wrought copper and copper alloys; actual supply and cold-heading suitability require separate confirmation. Table 3, note c: total impurities are the sum of measured contents of the impurity elements listed in the table.

Combined limits

Combined-element limits
    Elements requiring measured values from the same heat

      Verification notes

      The original scanned standard, Table 3 was manually checked cell by cell; Coupled elements and application-specific footnotes require separate verification
      WhatsApp Technical enquiry →