← BackMaterial grade directory

H80

2 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.

Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.

Open condition selection, comparison and carbon-equivalent tools for H80 →

H80 · GB/T 5231-2001

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Copper and copper alloys
Material form
Reference record
Original record status
Original standard verified
Standard edition
GB/T 5231-2001
Table / clause
Table 2 and footnotes
PDF page references
1、3、4、5、6、7、8、9、10、11、12、13、14

Carbon-equivalent reference

Estimates are presented separately for each applicable composition condition. Match the actual ordering conditions; ranges must not be combined.

Table 2 standard condition
IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category
Note 2, special applications: specified impurity limits and total ≤0.20%
IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category
Table 2, Note 1: Fe ≤0.030% for non-magnetic brass; do not automatically combine with other purchasing conditions
IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category

Composition record (conditional branches apply; this is not an unconditional requirement)

ElementComposition requirement
Cu79.0 ~ 81.0
Fe≤ 0.1 (lower limit not stated)
Pb≤ 0.03 (lower limit not stated)
Ni≤ 0.5 (lower limit not stated)

Applicability and limitations

Mass fraction wt%; Under 2.2, elements with specified lower and upper limits are alloying constituents; a single value is a minimum for copper and a maximum for other elements. A dash means unspecified; it is not entered as zero; Cu+Ag and Ni+Co are subject to combined ranges and are not converted into independent element ranges. The balance remains a balance; subtracting independent maxima does not establish a guaranteed range. Total impurities include all relevant impurities; The sum of listed elements is only a necessary condition and cannot replace complete impurity analysis. Product forms in the original document define the applicable wrought-product scope; they do not establish confirmed supply of cold-heading wire or final properties. Zn is the balance; Total impurities ≤0.3%. Table 2, note 1: Fe≤0.030% applies to nonmagnetic brass only where nonmagnetic performance is expressly required; Ordinary conditions are not automatically tightened.

Combined limits

Combined-element limits
    Elements requiring measured values from the same heat
      Element-sum limits
      • Elements concerned
        • Fe
        • Pb
        • Ni
        Upper limit
        0.3

      Original condition-branch records

      Table 2 standard condition

      ElementComposition requirement
      Cu79.0 ~ 81.0
      Fe≤ 0.1 (lower limit not stated)
      Pb≤ 0.03 (lower limit not stated)
      Ni≤ 0.5 (lower limit not stated)

      Note 2, special applications: specified impurity limits and total ≤0.20%

      ElementComposition requirement
      Cu79.0 ~ 81.0
      Fe≤ 0.07 (lower limit not stated)
      Pb≤ 0.03 (lower limit not stated)
      Ni≤ 0.5 (lower limit not stated)
      Sb≤ 0.002 (lower limit not stated)
      P≤ 0.005 (lower limit not stated)
      As≤ 0.005 (lower limit not stated)
      S≤ 0.002 (lower limit not stated)
      Combined limits
      Element-sum limits
      • Elements concerned
        • Fe
        • Pb
        • Ni
        • Sb
        • P
        • As
        • S
        Upper limit
        0.2

      Table 2, Note 1: Fe ≤0.030% for non-magnetic brass; do not automatically combine with other purchasing conditions

      ElementComposition requirement
      Cu79.0 ~ 81.0
      Fe≤ 0.03 (lower limit not stated)
      Pb≤ 0.03 (lower limit not stated)
      Ni≤ 0.5 (lower limit not stated)

      A condition branch must be selected

      Yes

      Verification notes

      The official GB/T 5231—2001 tables 1–4 and applicable footnotes were checked row by row against the source. The condition conflict for seven grades whose Fe content is incompatible with non-magnetic requirements is retained; it is not applied automatically.

      H80 · GB/T 5231-2012

      Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

      Material category
      Copper and copper alloys
      Material form
      Reference record
      Original record status
      Original standard verified
      Standard edition
      GB/T 5231-2012
      Table / clause
      Table 3, row 4, designation C24000
      PDF page references
      7、9

      Carbon-equivalent reference

      Estimates are presented separately for each applicable composition condition. Match the actual ordering conditions; ranges must not be combined.

      Table 3, ordinary condition, total impurities ≤0.30%
      IIW / CEV: not directly applicable to this material category
      Pcm (Ito–Bessyo): not directly applicable to this material category
      CET: not directly applicable to this material category
      Table 3, note b, special applications: specified impurity limits and total impurities ≤0.20%
      IIW / CEV: not directly applicable to this material category
      Pcm (Ito–Bessyo): not directly applicable to this material category
      CET: not directly applicable to this material category

      Composition record (conditional branches apply; this is not an unconditional requirement)

      ElementComposition requirement
      Cu78.5 ~ 81.5
      Fe≤ 0.05 (lower limit not stated)
      Pb≤ 0.05 (lower limit not stated)

      Applicability and limitations

      Mass fraction wt%; GB/T5231—2012, Table 3, row 4, designation C24000. Zn is the balance; The listed total impurities ≤0.3%, covering all impurities other than the main components; the partial sum of listed elements cannot replace the total impurity analysis. Clause 2.2: single values for other impurity elements are maxima; Unlisted limits shall be negotiated between the supplier and the purchaser and cannot be filled as zero. This standard covers wrought copper and copper-alloy designations and chemical composition; actual supply of cold-heading wire is not inferred. Table 3 Note b: Special application H70/H80 has separate limit values Fe≤0.07%, Sb≤0.002%, P≤0.005%, As≤0.005%, S≤0.002%, with total impurities ≤0.20%; Application conditions must be specified.

      Combined limits

      Combined-element limits
        Elements requiring measured values from the same heat

          Original condition-branch records

          Table 3, ordinary condition, total impurities ≤0.30%

          ElementComposition requirement
          Cu78.5 ~ 81.5
          Fe≤ 0.05 (lower limit not stated)
          Pb≤ 0.05 (lower limit not stated)

          Table 3, note b, special applications: specified impurity limits and total impurities ≤0.20%

          ElementComposition requirement
          Cu78.5 ~ 81.5
          Fe≤ 0.07 (lower limit not stated)
          Pb≤ 0.05 (lower limit not stated)
          Sb≤ 0.002 (lower limit not stated)
          P≤ 0.005 (lower limit not stated)
          As≤ 0.005 (lower limit not stated)
          S≤ 0.002 (lower limit not stated)
          Total impurity upper limit
          0.2

          A condition branch must be selected

          Yes

          Verification notes

          Each cell in row 4 of Table 3 in the scanned original, together with applicable footnotes, was checked manually
          WhatsApp Technical enquiry →