C17C
5 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.
Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.
Open condition selection, comparison and carbon-equivalent tools for C17C →C17C · EN 10263
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Drawn wire
- Original record status
- Reference transcription of standard
- Standard edition
- BS EN 10263-2:2017
- Table / clause
- Table 2
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Applicability and limitations
BS EN 10263-2:2017; Heat analysis, mass percent; Values without a stated range are maxima; Notes below the table are retained. No edition is stated on the website; Displayed under this source edition; contract applicability is not established
Verification notes
Standard source: BS EN 10263-2:2017 · Table 2View associated products →C17C · ISO 4954
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Cold-heading wire
- Original record status
- Reference transcription of standard
- Standard edition
- ISO 4954:2018
- Table / clause
- Table A.2
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Cr | ≤ 0.3 (lower limit not stated) |
| Ni | ≤ 0.3 (lower limit not stated) |
| Mo | ≤ 0.1 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
| Cu | ≤ 0.3 (lower limit not stated) |
| Cr+Ni+Mo | ≤ 0.5 (lower limit not stated) |
Applicability and limitations
ISO 4954:2018; Heat analysis, mass percent; Values without stated ranges are maxima; See the original page for the complete table notes. No edition is stated on the website; Displayed under this source edition; contract applicability is not established; ISO4954:2018 Table A.2 applies to steels not intended for heat treatment after cold working, heat analysis wt%; The original text specifies Cr+Ni+Mo total ≤0.50%; in addition to individual element limits, the total must also be satisfied; Elements not entered shall remain unknown and not be treated as 0; Optional deoxidation/aluminum substitution and Mn agreements shall still be verified against explicit ordering conditions.
Combined limits
- Element-sum limits
- Elements concerned
- Cr
- Ni
- Mo
- Upper limit
- 0.5
Verification notes
Standard source: ISO 4954:2018 · Table A.2View associated products →C17C · ISO 4954-2018
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material category
- Carbon steel
- Subcategory
- Steel not heat-treated after cold working
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- ISO 4954:2018
- Table / clause
- Table A.2
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Cr | ≤ 0.3 (lower limit not stated) |
| Ni | ≤ 0.3 (lower limit not stated) |
| Mo | ≤ 0.1 (lower limit not stated) |
| Cu | ≤ 0.3 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Applicability and limitations
ISO 4954:2018, Table A.2 gives heat analysis; A single value is a maximum; a dash is not zero. ; Product-analysis tolerances are listed separately under Table 2/3 of the standard and do not directly widen the heat-analysis composition ranges. ; Applicable to steels that do not undergo heat treatment after cold working. ; Al may be replaced by other elements with similar effects; Al cannot be required to reach the lower limit listed in the table without conditions. ; A lower Mn may be specified for C2C/C20C/C20GC/C25C, with a range width of 0.20%; Subject to ordering agreement.
Combined limits
- Element-sum limits
- Elements concerned
- Cr
- Ni
- Mo
- Upper limit
- 0.5
- Conditional composition lower limit
- Al
- Applicable conditions
- May be replaced by other elements with a similar effect
Verification notes
The original standard, Table A.2 and footnotes have been checkedC17C · EN 10263-2-2017
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- EN 10263-2-2017
- Table / clause
- Table 2 and notes a–f
Carbon-equivalent reference
Estimates are presented separately for each applicable composition condition. Match the actual ordering conditions; ranges must not be combined.
Default composition in Table 2, Al deoxidation condition
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected
Default composition in Table 2, Al deoxidation condition; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
Composition record (conditional branches apply; this is not an unconditional requirement)
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Applicability and limitations
Heat-analysis mass fractions wt%; See Table 3 separately for product-analysis tolerances. ; Note b permits aluminum to be replaced by other elements with a similar effect; composition of replacement elements must not be inferred before they are identified. ; Unlisted elements must not be intentionally added without purchaser consent, except additions needed to finish the heat; Residual elements must not impair properties or suitability; unlisted content does not mean zero. ; This standard covers cold heading and cold extrusion; actual delivery condition, dimensions, surface and mechanical properties require separate verification, and no supply product is created automatically.
Original condition-branch records
Default composition in Table 2, Al deoxidation condition
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | 0.15 ~ 0.25 |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Default composition in Table 2, Al deoxidation condition; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | 0.15 ~ 0.25 |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
A condition branch must be selected
YesVerification notes
The original Table 2 and footnotes have been checked; Optional additions and agreed provisions require separate confirmationC17C · DIN EN 10263-2-2018
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- DIN EN 10263-2:2018-02
- Table / clause
- Tabelle 2 and footnote a–f; Tabelle 3 product-analysis tolerances require separate verification
- PDF page references
- 1、9
- Unit
- Mass fraction (wt%)
- Analysis type
- Heat analysis
Carbon-equivalent reference
Estimates are presented separately for each applicable composition condition. Match the actual ordering conditions; ranges must not be combined.
Default composition in Table 2, Al deoxidation condition
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected
Default composition in Table 2, Al deoxidation condition; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
Composition record (conditional branches apply; this is not an unconditional requirement)
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Applicability and limitations
DIN EN 10263-2:2018-02 is the German-language edition of EN 10263-2:2017; This record was verified against heat analysis and footnotes in Table 2 of the official German edition. ; Heat-analysis mass fractions wt%; See Table 3 separately for product-analysis tolerances. ; Note b permits aluminum to be replaced by other elements with a similar effect; composition of replacement elements must not be inferred before they are identified. ; Unlisted elements must not be intentionally added without purchaser consent, except additions needed to finish the heat; Residual elements must not impair properties or suitability; unlisted content does not mean zero. ; This standard covers cold heading and cold extrusion; actual delivery condition, dimensions, surface and mechanical properties require separate verification, and no supply product is created automatically.
Original condition-branch records
Default composition in Table 2, Al deoxidation condition
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | 0.15 ~ 0.25 |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
| Al | 0.02 ~ 0.06 |
Default composition in Table 2, Al deoxidation condition; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | ≤ 0.1 (lower limit not stated) |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |
Agreed hot-dip galvanizing, Si 0.15–0.25%; Mechanical properties in Table 4 may be affected; Al is replaced by elements with equivalent effect; the replacement elements and contents require separate verification
| Element | Composition requirement |
|---|---|
| C | 0.15 ~ 0.19 |
| Si | 0.15 ~ 0.25 |
| Mn | 0.65 ~ 0.85 |
| P | ≤ 0.025 (lower limit not stated) |
| S | ≤ 0.025 (lower limit not stated) |