← BackMaterial grade directory

A312 800H

1 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.

Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.

Open condition selection, comparison and carbon-equivalent tools for A312 800H →

A312 800H · ASTM A312/A312M-2025

Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results

Material category
Stainless steel
Subcategory
Austenitic stainless steel
Material form
Reference record
Original record status
Original text of the historical edition verified
Standard edition
ASTM A312/A312M-2017
Table / clause
Table 1, footnotes A–M and clause 7.1
PDF page references
1、2、6

Carbon-equivalent reference

IIW / CEV: not directly applicable to this material category
Pcm (Ito–Bessyo): not directly applicable to this material category
CET: not directly applicable to this material category

Composition

ElementComposition requirement
C0.05 ~ 0.1
Mn≤ 1.5 (lower limit not stated)
P≤ 0.045 (lower limit not stated)
S≤ 0.015 (lower limit not stated)
Si≤ 1.0 (lower limit not stated)
Cr19.0 ~ 23.0
Ni30.0 ~ 35.0
Ti0.15 ~ 0.6
Cu≤ 0.75 (lower limit not stated)
Al0.15 ~ 0.6
Fe≥ 39.5 (upper limit not stated)

Applicability and limitations

Table 1, mass percent; A single value is a maximum; ellipses mean unspecified and are not entered as zero. ; Clause 7.1 requires compliance with Table 1; The general A999/A999M requirements in Clause 5.1 still apply; only the chemical-composition table was checked in this batch. ; Austenitic steel pipe standard; This does not directly establish cold-heading wire suitability or compliance with all product acceptance requirements. ; Footnote C: the nitrogen-analysis method is agreed between purchaser and supplier. ; Footnote J: Fe is calculated as 100 minus the sum of other specified elements and must be at least 39.5%.

Combined limits

Combined-element limits
  • Requirement
    Sum of other specified elements ≤60.50%
    Element coefficient
    C
    1
    Mn
    1
    P
    1
    S
    1
    Si
    1
    Cr
    1
    Ni
    1
    Ti
    1
    Cu
    1
    Al
    1
    Upper limit
    60.5
  • Requirement
    Fe=100 minus the sum of other specified elements
    Element coefficient
    C
    1
    Mn
    1
    P
    1
    S
    1
    Si
    1
    Cr
    1
    Ni
    1
    Ti
    1
    Cu
    1
    Al
    1
    Fe
    1
    Lower limit
    100
    Upper limit
    100

Verification notes

Original edition 2017, Table 1 and footnotes are used; Edition 2025 has not been verified; identical composition across the two editions is not claimed.
WhatsApp Technical enquiry →