1100
3 source records. Standards, editions and conditions are presented separately; matching grade names do not establish interchangeability.
Refer to each source for mass fractions and analysis type. Missing values are not treated as 0. Manufacturer typical values, standard guarantees and measured heat results must remain separate. Use the material selector for calculations and condition selection.
Open condition selection, comparison and carbon-equivalent tools for 1100 →1100 · GB/T 3190—1996
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material category
- Aluminum and aluminum alloys
- Subcategory
- Aluminum and aluminum alloys
- Material form
- Reference record
- Original record status
- Original-standard record
- Standard edition
- GB/T 3190—1996
- Table / clause
- Table 1; Clause 4.1~4.5 · Footnotes
- PDF page references
- 3、5、13
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| Cu | 0.05 ~ 0.2 |
| Mn | ≤ 0.05 (lower limit not stated) |
| Zn | ≤ 0.1 (lower limit not stated) |
| Al | ≥ 99.0 (upper limit not stated) |
Applicability and limitations
GB/T 3190—1996, Table 1, mass percent; Unspecified elements are not treated as zero. ; This standard covers chemical composition of wrought aluminum and aluminum alloys; This does not establish cold-heading suitability, actual supply or finished-product properties. ; Al is listed as a minimum content; Aluminum content is calculated by difference under Clause 4.1/4.2, using the specified inclusion thresholds and precision; unmeasured elements must not be treated as zero. ; Individual and combined limits for other impurities concern only the other elements defined in Clause 4.3 of the standard, not the sum of all principal alloying elements; Missing impurity test results must not be treated as zero. ; Table 1, footnote 1: for welding electrodes and surfacing applications, beryllium content must not exceed 0.0008%.
Combined limits
- Combined-element limits
- Requirement
- Si+Fe (GB/T 3190—1996, Table 1)
- Element coefficient
- Si
- 1
- Fe
- 1
- Lower limit
- Not stated
- Upper limit
- 0.95
- Elements requiring measured values from the same heat
- Fe
- Si
- Purity calculation rules in the source
- PDF page references
- 3
- Purity from 99.00% to below 99.90%
- Al = 100 minus the sum of all other elements present at ≥0.010%; before summing, express each element to 0.0X%.
- Purity from 99.90% to 99.99%
- Al = 100 minus the sum of all other elements present at ≥0.001%; before summing, express each element to 0.00X%, then round the result to 0.0X%.
- Rounding rules
- Follow GB/T 8170; do not treat unspecified elements as zero or apply ordinary remainder calculations directly.
- Purity requires technical review
- Yes
- Other-impurity requirements in the source
- Each other impurity
- 0.05
- Sum of other impurities
- 0.15
- Other impurities require technical review
- Yes
- Conditional requirements in the source
- Footnote
- 1
- Source conditions
- For welding electrodes and surfacing applications, beryllium content must not exceed 0.0008%.
- Automatic evaluation implemented
- No
1100 · JIS H 4040-2015
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- JIS H 4040:2015
- Table / clause
- Table 1: applicable product forms and designations; Table 2: chemical composition and footnotes.
- PDF page references
- 15
- Unit
- Mass fraction (%)
- Analysis type
- Chemical composition (refer to the source notes for the analysis type)
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| Cu | 0.05 ~ 0.2 |
| Mn | ≤ 0.05 (lower limit not stated) |
| Zn | ≤ 0.1 (lower limit not stated) |
| Al | ≥ 99.0 (upper limit not stated) |
Applicability and limitations
Table 2 coupled limit: Si+Fe≤0.95%; a combined maximum is not treated as an independent maximum for each element. ; Table 2, footnote b: Be≤0.0003% applies only to filler rods and welding wire; it is not a default restriction for all forms. ; Each otherwise unlisted element is ≤0.05%; this is not automatically treated as a known limit for a specific element. ; The combined total of otherwise unlisted elements is ≤0.15%. ; Table 1 applicable forms: extruded bars, cold-drawn bars and cold-drawn wire; Form codes correspond only to Table 1 of this edition and do not establish supply by Creation Group. ; Table 2 gives chemical composition in mass percent; Mechanical properties, dimensions and delivery condition require separate verification against the applicable original tables and order requirements.
Verification notes
2015: Tables 1 and 2 in the original English edition corrected page by page and cell by cell; alloy designation 1100; original PDF page 15, Table 21100 · JIS H 4040-2006
Chemical composition source verified; this does not verify every standard clause, actual supply or measured heat results
- Material form
- Reference record
- Original record status
- Original standard verified
- Standard edition
- JIS H 4040:2006
- Table / clause
- Table 1: applicable product forms and designations; Table 2: chemical composition and footnotes.
- PDF page references
- 8
- Unit
- Mass fraction (%)
- Analysis type
- Chemical composition (refer to the source notes for the analysis type)
Carbon-equivalent reference
Composition
| Element | Composition requirement |
|---|---|
| Cu | 0.05 ~ 0.2 |
| Mn | ≤ 0.05 (lower limit not stated) |
| Zn | ≤ 0.1 (lower limit not stated) |
| Al | ≥ 99.0 (upper limit not stated) |
Applicability and limitations
Table 2 coupled limit: Si+Fe≤0.95%; a combined maximum is not treated as an independent maximum for each element. ; Table 2, footnote 2: Be≤0.0003% applies only to filler rods and welding wire; it is not a default restriction for all forms. ; Each otherwise unlisted element is ≤0.05%; this is not automatically treated as a known limit for a specific element. ; The combined total of otherwise unlisted elements is ≤0.15%. ; Table 1 applicable forms: extruded bars, cold-drawn bars and cold-drawn wire; Form codes correspond only to Table 1 of this edition and do not establish supply by Creation Group. ; Table 2 gives chemical composition in mass percent; Mechanical properties, dimensions and delivery condition require separate verification against the applicable original tables and order requirements.